Omron HEM7121 Standard Blood Pressure Monitor

ALWAYS READ & FOLLOW THE INSTRUCTIONS FOR USE & HEALTH WARNINGS. FOR PEOPLE WITH HIGH BLOOD PRESSURE. CONSULT YOUR DOCTOR TO EVALUATE THE READINGS. CHECK YOUR DEVICE PERIODICALLY FOR ACCURACY.

Description

•Easy to Use One-Touch Operation
•Intellisense Technology™
Automatically applies the right amount of pressure for fast, accurate and more comfortable measurements
•30 Reading Memory
30 memory storage allows you to review the last 30 readings with a touch of a button
•Soft Cuff (Med-Lge)
22-42cm arm circumference
•Cuff Wrapping Guide
Indicator confirms the cuff has been wrapped correctly on the user’s arm
•Irregular Heartbeat Indicator
This monitor can detect an irregular heartbeat (arrhythmia) which can assist with early diagnosis*. If an irregular heartbeat is detected, an indicator icon will appear alerting the user to consult with a medical professional.
*N.B. Only a doctor can diagnose arrhythmia
•Hypertension Indicator
Alerts you if your blood pressure reading exceeds internationally recognised guidelines for normal home blood pressure levels
•Body Movement Indicator
Alerts user if anybody movement has occurred during the blood pressure reading
•LCD Display
•Powered by 4 x AA Batteries
Optional extra: AC adaptor



Boxed Contents: Main unit, arm cuff, instruction manual, 4 x AA batteries

Warnings

Please read all Safety Warnings provided with the product prior to using. •Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, pregnancy, pre-eclampsia, masectomy, renal disease or severe blood flow problems or blood disorders as cuff inflation can cause bruising •Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous •Do not adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High / Low Blood Pressure •The monitor is not intended to be a diagnostic device •Do not use the unit for any purpose other than measuring blood pressure •Do not use the device on the injured arm or the arm under medical treatment •Do not wrap the arm cuff on the arm while being on an intravenous drip or blood transfusion •Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt •Do not apply or inflate the arm cuff around any body parts other than your upper arm •Do not take measurements more than necessary. It may cause bruising due to blood flow interference •Remove the arm cuff if it does not start deflating during the measurement •The air tube or the AC adapter cable may cause accidental strangulation in infants •Keep out of reach of children. Contains small parts that may cause a choking hazard if swallowed •If there are any abnormalities during the measurement, remove the arm cuff •Do not use this device on infants, children or persons who cannot express themselves •Do not inflate the arm cuff more than necessary •Stop using this monitor and consult your doctor if you experience skin irritation or discomfort •Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results •Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit •Do not use the device with other medical electrical (ME) equipment simultaneously •Do not use this monitor in areas containing high frequency (HF) surgical equipment, magnetic resonance imaging (MRI) equipment, computerized tomography (CT) scanners or in oxygen rich environments •Follow the battery/ AC adaptor instructions carefully


Ingredients

Cuff- LATEX FREE

Direction

Please read the full Instructions for Use provided with the product prior to using. •Avoid bathing, drinking alcohol/caffeine, smoking, exercising and eating for 30 minutes before taking a measurement •Rest for at least 5 minutes before taking the measurement •Sit upright on a chair with your legs uncrossed and feet flat on the floor, with your back and arm being supported •Remove tight-fitting clothing from your arm. Do not roll up a tight sleeve. Do not place the arm cuff over thick clothes •Wrap the arm cuff firmly in place around the left upper arm. Please see instruction manual if needing to use the right arm. •The bottom edge of the arm cuff should be 1 to 2 cm above your elbow •The air tube should be on the inside of your arm and aligned with your middle finger •Rest your arm on a table so that the arm cuff is at the same level as your heart •Ensure solid connection of the airplug and cuff to main unit •Ensure you remain still and do not talk during the measurement •Press the START/STOP button •The cuff will inflate and a result will display on the screen (approx. 30-60 secs) •The reading will be automatically saved in the memory

Storage Instructions

-20 to +60°C / 10 to 95% RH / 700-1060 hPa

Omron HEM7121 Standard Blood Pressure Monitor

Product form

SKU: 12980

$137.95  $114.99

In Stock—Ready to Ship

    • Safe and Secure Shopping
    • Always read the label and follow the directions for use. If symptoms persist, talk to your health professional. Dietary supplements can only be of assistance if dietary intake is inadequate. Not to be used in children under 2 years of age without medical
    • Delivery in 2-10 business days
    ALWAYS READ & FOLLOW THE INSTRUCTIONS FOR USE & HEALTH WARNINGS. FOR PEOPLE WITH HIGH BLOOD PRESSURE. CONSULT YOUR DOCTOR TO EVALUATE THE READINGS. CHECK YOUR DEVICE PERIODICALLY FOR ACCURACY.

    Description

    •Easy to Use One-Touch Operation
    •Intellisense Technology™
    Automatically applies the right amount of pressure for fast, accurate and more comfortable measurements
    •30 Reading Memory
    30 memory storage allows you to review the last 30 readings with a touch of a button
    •Soft Cuff (Med-Lge)
    22-42cm arm circumference
    •Cuff Wrapping Guide
    Indicator confirms the cuff has been wrapped correctly on the user’s arm
    •Irregular Heartbeat Indicator
    This monitor can detect an irregular heartbeat (arrhythmia) which can assist with early diagnosis*. If an irregular heartbeat is detected, an indicator icon will appear alerting the user to consult with a medical professional.
    *N.B. Only a doctor can diagnose arrhythmia
    •Hypertension Indicator
    Alerts you if your blood pressure reading exceeds internationally recognised guidelines for normal home blood pressure levels
    •Body Movement Indicator
    Alerts user if anybody movement has occurred during the blood pressure reading
    •LCD Display
    •Powered by 4 x AA Batteries
    Optional extra: AC adaptor



    Boxed Contents: Main unit, arm cuff, instruction manual, 4 x AA batteries

    Warnings

    Please read all Safety Warnings provided with the product prior to using. •Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, pregnancy, pre-eclampsia, masectomy, renal disease or severe blood flow problems or blood disorders as cuff inflation can cause bruising •Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous •Do not adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High / Low Blood Pressure •The monitor is not intended to be a diagnostic device •Do not use the unit for any purpose other than measuring blood pressure •Do not use the device on the injured arm or the arm under medical treatment •Do not wrap the arm cuff on the arm while being on an intravenous drip or blood transfusion •Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt •Do not apply or inflate the arm cuff around any body parts other than your upper arm •Do not take measurements more than necessary. It may cause bruising due to blood flow interference •Remove the arm cuff if it does not start deflating during the measurement •The air tube or the AC adapter cable may cause accidental strangulation in infants •Keep out of reach of children. Contains small parts that may cause a choking hazard if swallowed •If there are any abnormalities during the measurement, remove the arm cuff •Do not use this device on infants, children or persons who cannot express themselves •Do not inflate the arm cuff more than necessary •Stop using this monitor and consult your doctor if you experience skin irritation or discomfort •Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results •Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit •Do not use the device with other medical electrical (ME) equipment simultaneously •Do not use this monitor in areas containing high frequency (HF) surgical equipment, magnetic resonance imaging (MRI) equipment, computerized tomography (CT) scanners or in oxygen rich environments •Follow the battery/ AC adaptor instructions carefully


    Ingredients

    Cuff- LATEX FREE

    Direction

    Please read the full Instructions for Use provided with the product prior to using. •Avoid bathing, drinking alcohol/caffeine, smoking, exercising and eating for 30 minutes before taking a measurement •Rest for at least 5 minutes before taking the measurement •Sit upright on a chair with your legs uncrossed and feet flat on the floor, with your back and arm being supported •Remove tight-fitting clothing from your arm. Do not roll up a tight sleeve. Do not place the arm cuff over thick clothes •Wrap the arm cuff firmly in place around the left upper arm. Please see instruction manual if needing to use the right arm. •The bottom edge of the arm cuff should be 1 to 2 cm above your elbow •The air tube should be on the inside of your arm and aligned with your middle finger •Rest your arm on a table so that the arm cuff is at the same level as your heart •Ensure solid connection of the airplug and cuff to main unit •Ensure you remain still and do not talk during the measurement •Press the START/STOP button •The cuff will inflate and a result will display on the screen (approx. 30-60 secs) •The reading will be automatically saved in the memory

    Storage Instructions

    -20 to +60°C / 10 to 95% RH / 700-1060 hPa
    Recently viewed products

    © 2026 Direct Chemist Outlet Online,

      • American Express
      • Apple Pay
      • Google Pay
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa
      Login

      Forgot your password?

      Don't have an account yet?
      Create account